Immersion Cooling Container BC10 MEGA Support Up to 96 AntMiner S19/M50 Support CustomizationContact us WhatsApp: +86 15221042815 Please Click: [wa. me 8615221042815] Telegram: +86 18201810091 Please Click: [t. me Contact_Jinglemining] Email: service@jinglemining. com IMMERSION COOLING CONTAINER BC10Designed for large scale mining Immersion Cooling BC10 MEGA Introduction Video Liquid Immersion Cooling: Technical Advantages Precise temperature control Provides a controlled environment for chipsets and eliminates electron migration phenomena
Shopping security
Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
IMMERSION COOLING CONTAINER BC10——Designed for large-scale mining
Immersion Cooling BC10 MEGA Introduction Video
Liquid Immersion Cooling: Technical Advantages
• Precise temperature control – Provides a controlled environment for chipsets and eliminates “electron migration phenomena” caused by high heat.
• Stable operation – Reduces failures, increases uptime-rate close to 100%.
• Longer lifecycle – The mining machines are isolated from the air and free from dust, static electricity, short circuit, oxidation, and fan vibration, extending the lifecycle of the mining machine to more than 5 years in average.
• Low noise – Eliminates the noise problem of air cooling and allows to deploy in residential and commercial areas.
• Overclocked hashrate – Up to 60% of hashrate overclocking will shorten the return cycle and boost the ROI.
• Reduced O&M cost – Stable operating capability combined with FH remote monitoring system can reduce maintenance costs by up to 90%.
• Lower cooling cost – FH intelligent power management system can reduce cooling energy consumption (PUE 1.02~1.05) and carbon emission more effectively.
Specifications
Dimensions(L*W*H)(mm)
2991*2438*2591
2991*2438*2591
Shipping Weight(T)
3
3
Operating Weight(T)
6
6
Coolant Capacity (L)
3600
3600
Cycle Mode
Single loop
Single loop
Miner Capacity
96 S19/M50
96 S19/M50
Tank Quantity
B24 Tank*4
B24 Tank*4
Operating Temperature(℃)
-25°C ~55℃
-25°C ~55℃
Electrical Performance (- /✓ optional/standard)
–
BASIC
PRO
Input Voltage and Frequency
3-phase 350-480V 50/60Hz
3-phase 350-480V 50/60Hz
Max Power Load (kW)
444
706
Output Voltage and Frequency
Single-phase 200-277V 50/60Hz
Single-phase 200-277V 50/60Hz
Safety Certification
CE/UL
CE/UL
Operating Power(kW)
25
33
Power Distribution Cabinets(A)
630Ax1 *1
1000Ax1 *1
PDU
Smart PDU * 4
Smart PDU * 8
Inlet Cable
The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:L1 4-wires cable 1AWG(42.4mm x4) x1 *1L2 4-wires cable 1AWG(42.4mm x4) x1 *1L3 4-wires cable 1AWG(42.4mm x4) x1 *1N 4-wires cable 1AWG(42.4mm x4) x1 *1PE 1-wire cable 1AWG(42.4mm) x1 *1
The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:L1 4-wires cable 3/0AWG(85mm x4) x1 *1L2 4-wires cable 3/0AWG(85mm x4) x1 *1L3 4-wires cable 3/0AWG(85mm x4) x1 *1N 4-wires cable 3/0AWG(85mm x4) x1 *1PE 1-wire cable 3/0AWG(85mm) x1 *1
Smart Meter
–
✓
Integrated Wiring
✓
✓
Network
✓
✓
UPS
–
–
SPD
✓
✓
Cooling Capacity
–
BASIC
PRO
Cooling Capacity(kW)
360
480
Cooling Type
Closed water cooling tower
or Dry cooler
Closed water cooling tower
or Dry cooler
Inlet Temperature(℃)
45
45
Outlet Temperature(℃)
60
60
Design Reference Temperature (℃)
35
35
Note: About the transportation of liquid cooling equipment
For most areas, the liquid cooling equipment will be shipped to you via sea freight. Ports and receiving points in different regions will incur different shipping charges. It is recommended that you contact customer service to confirm address details and calculate shipping costs before placing an order.
Show More
Immersion Cooling Container BC10 MEGA Support Up to 96 AntMiner S19/M50 Support Customization