20% OFF shipping at lifisolutions.eu on orders over $79 + up to 10% OFF products
lifisolutions.eu
home > Wilkins 112-950XL3 | Reduced Pressure Principle Backflow Assembly > Wilkins 112-950XL3 | Reduced Pressure Principle Backflow Assembly
download picture
Wilkins 112-950XL3 | Reduced Pressure Principle Backflow AssemblyNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 112 950XL3 is a reduced pressure principle backflow prevention assembly designed to protect potable water systems against both backsiphonage and backpressure contamination where a potential health hazard exists. Key Specifications: Size: 1 1 2 Inches Maximum Working Pressure: 25 175 PSI Maximum Temperature: 180F (82C) Notable
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 112-950XL3 is a reduced pressure principle backflow prevention assembly designed to protect potable water systems against both backsiphonage and backpressure contamination where a potential health hazard exists.

 

Key Specifications:

  • Size: 1 1/2 Inches
  • Maximum Working Pressure: 25/175 PSI
  • Maximum Temperature: 180°F (82°C)
  • Notable Certifications: ASSE 1013, cUPC, CSA
  • End Connections: Threaded FNPT

 

Other Related Variants:

  • 114-950XL3: 1 1/4 Inch model size
  • 1-950XL3: 1 Inch model size
  • 2-950XL3: 2 Inch model size
  • 34-950XL3: 3/4 Inch model size

 

Materials:

  • Body: Low Lead Bronze ASTM B584
  • Access Covers: Low Lead Cast Bronze ASTM B584
  • Fasteners: 300 Series Stainless Steel
  • Elastomers: Silicone (FDA Approved)
  • Elastomers: Buna Nitrile (FDA Approved)
  • Polymers: Noryl™
  • Springs: 300 Series Stainless Steel
  • Ball Valve Handles: Stainless Steel

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified; C-UL Classified; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 & 372

 

Features & Benefits:

  • Health Hazard Protection: Provides protection against both backsiphonage and backpressure of contaminated water into potable water supply systems.
  • Lead-Free Construction: Meets NSF/ANSI/CAN 372 with less than 0.25% weighted average lead content, ideal for potable water applications.
  • Full Port Ball Valves: Equipped with full port QT ball valves and integral test fittings for easy maintenance and testing accessibility.
  • Durable Materials: Constructed with low lead bronze body, 300 series stainless steel fasteners and springs, and FDA-approved elastomers for long-lasting performance.

 

FAQ

 

Q: What is the minimum working pressure required for the Zurn 112-950XL3?

A: The Zurn 112-950XL3 requires a minimum working water pressure of 25 PSI and can operate up to a maximum of 175 PSI.

Q: Where should the Wilkins 112-950XL3 be installed?

A: The unit must be installed 12 to 30 inches above an adequate drain with sufficient side clearance for testing and maintenance. The assembly must not be submerged and should be positioned so no part can come into contact with standing water.

Q: Is the 112-950XL3 compatible with pressure reducing valves?

A: Yes, for optimal performance, it is recommended to use the 112-950XL3 with suggested pressure reducing valve models including Model 500XL3, 600XL3, or 625XL3.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 112-950XL3 | Reduced Pressure Principle Backflow Assembly

Item no : 99164199467
sold recently : Login >>
US$ 640.00
Pay in 4 interest-free payments of $160.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 22 - Jul 27

Enjoy 20% off shipping

US$ 640.00

1-11

US$ 576.00

12-35

US$ 448.00

36-59

US$ 384.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches