20% OFF shipping at lifisolutions.eu on orders over $79 + up to 10% OFF products
lifisolutions.eu
home > P0950DF Foxboro I/A Series Datasheet & Technical Manual > P0950DF Foxboro I/A Series Datasheet & Technical Manual
download picture
P0950DF Foxboro I/A Series Datasheet & Technical ManualFoxboro P0950DF I A Series Termination Assembly The Foxboro P0950DF, also cataloged as the P0950DF Termination Assembly, operates as a dedicated hardware component for field wiring distribution and signal conditioning within I A Series Distributed Control System platforms. The hardware establishes direct physical connectivity between external analog sensors and primary processing units via the system baseplate interface, supporting eight independent
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Foxboro P0950DF I/A Series Termination Assembly

The Foxboro P0950DF, also cataloged as the P0950DF Termination Assembly, operates as a dedicated hardware component for field wiring distribution and signal conditioning within I/A Series Distributed Control System platforms. The hardware establishes direct physical connectivity between external analog sensors and primary processing units via the system baseplate interface, supporting eight independent input channels.

Hardware Specifications

Parameter Specification
Model P0950DF
Brand Foxboro (Schneider Electric)
Origin USA
Weight 400 g
Dimensions Standard I/A Series termination assembly footprint
Operating Temp -20 to +60 deg C
Power Consumption Sourced via FBM module backplane connection
Channel Capacity 8 analog input channels
Supported Signals Voltage (+/-10 V, +/-5 V, 0-10 V, 1-5 V), Current (0-20 mA, 4-20 mA), Thermocouple (J, K, T, E, S, R, B), RTD (Pt100, Pt1000, Cu50)
Termination Type Screw-clamp terminals (12-22 AWG)
Isolation Channel-to-channel and channel-to-ground isolation
Mounting DIN rail or rack base
Enclosure Rating IP20 (cabinet installation required)
Storage Temp -40 to +85 deg C

Process Control & DCS Instrumentation Properties

The component integrates high-density channel-to-channel and channel-to-ground isolation to eliminate common-mode noise and prevent ground loop interference across the eight input circuits. The hardware architecture accommodates multi-signal configurations, enabling concurrent processing of 4-20 mA HART loop protocol transmitters, voltage lines, RTD elements, and thermocouple inputs over separate channels. Automatic cold junction compensation (CJC) algorithms are sustained through localized temperature reference sensors embedded within the termination terminal array to prevent drift under variable ambient thermal loads.

Frequently Asked Questions

Q: How does the termination assembly handle diagnostic faults such as open-circuit conditions?

A: The physical board infrastructure provides raw signal diagnostic routing. When paired with compatible modules such as the FBM242 or FBM247, open-circuit and short-circuit conditions are detected at the channel level and reported directly to the DCS backplane.

Q: Is external power required to operate the P0950DF terminal array?

A: No external power feed is required. Operational current for the internal isolation circuits and reference point sensors is supplied directly from the host Fieldbus Module via the integrated backplane connection.

Field Installation Guidelines

  • Mounting Alignment: Secure the assembly onto standard DIN rails or dedicated rack bases. Verify that the structural locking tabs are completely latched to ensure physical stability against high-frequency cabinet vibrations.
  • Shield Grounding Protocol: Terminate instrument cable shields directly to the master instrumentation ground bus within the cabinet enclosure. Do not ground the cable shield at both the field device and the P0950DF terminals to prevent induced ground loops.
  • Wire Termination: Strip field conductors to factory-specified lengths and insert into the screw-clamp blocks (12-22 AWG). Torque all terminal screws to standard ratings to ensure continuous low-impedance electrical contact.

P0950DF Foxboro I/A Series Datasheet & Technical Manual

Item no : 53718295085
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches