home > Wilkins 1-975XLU | Reduced Pressure Principle Backflow Preventer, 1 Inches > Wilkins 1-975XLU | Reduced Pressure Principle Backflow Preventer, 1 Inches
download picture
Wilkins 1-975XLU | Reduced Pressure Principle Backflow Preventer, 1 InchesThe Wilkins 1 975XLU is a reduced pressure principle backflow preventer engineered for high hazard protection on potable water lines, safeguarding against both backsiphonage and backpressure contamination. Key Specifications: Size: 1 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable Certifications: ASSE 1013, cUPC, CSA B64. 4 End Connections: FNPT with union ball valves Other Related Variants: 34 975XLU: 3
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The Wilkins 1-975XLU is a reduced pressure principle backflow preventer engineered for high hazard protection on potable water lines, safeguarding against both backsiphonage and backpressure contamination.

 

Key Specifications:

  • Size: 1 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT with union ball valves

 

Other Related Variants:

  • 34-975XLU: 3/4 Inches version

 

Materials:

  • Main Valve Body: Cast Bronze ASTM B 584
  • Access Covers: Cast Bronze ASTM B 584
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers: Silicone and Buna Nitrile
  • Polymers: Noryl™
  • Springs: Stainless Steel, 300 Series

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; UL Classified; C-UL Classified; CSA Certified B64.4; AWWA Compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NYC MEA 425-89-M VOL 3

 

Features & Benefits:

  • High Hazard Protection: Provides comprehensive protection against both backsiphonage and backpressure of contaminated water into potable water supply systems.
  • Union Ball Valve Serviceability: Union ball valves allow easy removal of the assembly body from the line for winterization, testing, and maintenance without disrupting the entire system.
  • Durable Bronze Construction: Cast bronze body and access covers ensure long-lasting performance and corrosion resistance in demanding water service applications.
  • Accessible Check Valves: First and second checks are accessible for maintenance without removing the relief valve or entire device from the line, minimizing downtime.

 

FAQ

 

Q: What applications is the Zurn 1-975XLU suitable for?

A: The Zurn 1-975XLU is designed for installation on potable water service lines where high health hazard protection is required, including commercial and industrial applications requiring protection against contaminated water backflow.

Q: How does the union ball valve configuration benefit maintenance?

A: The union ball valves positioned between the body and shut-offs allow for easy body removal for winterization or maintenance without cutting pipes or disrupting the entire water line.

Q: What is the required installation height for the Wilkins 1-975XLU?

A: The Wilkins 1-975XLU must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance, and no part of the unit can be submerged.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 1-975XLU | Reduced Pressure Principle Backflow Preventer, 1 Inches

Item no : 36858945457
sold recently : Login >>
US$ 465.00
Pay in 4 interest-free payments of $116.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 22 - Jul 27

Enjoy 20% off shipping

US$ 465.00

1-11

US$ 418.50

12-35

US$ 325.50

36-59

US$ 279.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches