20% OFF shipping at lifisolutions.eu on orders over $79 + up to 10% OFF products
lifisolutions.eu
home > TSX P47425 Schneider Electric Power Supply | New & Original Stock > TSX P47425 Schneider Electric Power Supply | New & Original Stock
download picture
TSX P47425 Schneider Electric Power Supply | New & Original StockSchneider Electric TSX P47425 Modicon TSX Premium Series The Schneider Electric TSX P47425, also cataloged as the TSX P474 25 Power Supply Module, operates as a dedicated hardware component for supplying regulated DC power within Modicon TSX Premium PLC systems. Configured for high power distribution across the internal chassis backplane, this module directly executes raw AC to DC conversion loops, driving connected CPU and I O modules without inline
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Schneider Electric TSX P47425 Modicon TSX Premium Series

The Schneider Electric TSX P47425, also cataloged as the TSX-P474-25 Power Supply Module, operates as a dedicated hardware component for supplying regulated DC power within Modicon TSX Premium PLC systems. Configured for high-power distribution across the internal chassis backplane, this module directly executes raw AC-to-DC conversion loops, driving connected CPU and I/O modules without inline external step-down transformers.

Hardware Specifications

Parameter Specification
Model TSX P47425 (TSX-P474-25)
Brand Schneider Electric
Origin France
Weight 0.8 to 1.0 kg (2.60 lbs)
Dimensions 130 mm x 40 mm x 120 mm
Operating Temp 0 to +60 deg C
Power Consumption 600 W power rating
Input Voltage 100-240 V AC, 50/60 Hz
Output Voltage 24 VDC
Output Current Up to 25 A (depending on load configuration)
Isolation Galvanic isolation between input and output
Protection Matrices Overload, short-circuit, and thermal protection
Storage Temperature -40 to +85 deg C
Protection Class IP20
Certifications CE, UL, CSA, RoHS

Backplane Bus Communication Velocity Licences and Power Execution

The TSX P47425 establishes immediate electrical continuity upon mechanical insertion into the TSX Premium rack assembly. It energizes the communication traces, maintaining the exact voltage thresholds required to sustain standard backplane bus communication velocity across all active slots. By provisioning up to 25 A on the internal rail, the module mitigates downstream voltage sags during high-density I/O switching cycles, maintaining data bus signal integrity without forcing clock-cycle throttling or communication delays across remote sub-racks.

Frequently Asked Questions

Q: Does the TSX P47425 support hot-swapping under active rack backplane communication velocity?

A: No. Extraction or insertion of the primary power module while the AC input line is energized can generate severe voltage transients, causing data corruption on the system bus or permanent electrical damage to the master processor.

Q: What are the internal failure states if the total output current demand exceeds 25 A?

A: The module transitions into an overload protection state, folding back the 24 VDC output loop to prevent thermal destruction. Once the over-current condition is physically isolated, the system executes an automated recovery cycle depending on the specific hardware revision.

Q: Can this unit run on DC input voltage sources instead of the nominal 100-240 VAC range?

A: No. The internal rectifier and transformer stages are explicitly engineered for 50/60 Hz alternating current. Connecting a DC source to the primary input terminals will prevent power conversion and may damage the front-end input stage.

Field Installation Guidelines

  • Mounting Orientation: Slide the unit firmly into its designated power supply slot on the Modicon TSX Premium rack. Ensure the locking mechanisms lock securely to guarantee reliable grounding contact with the backplane frame.
  • Cabinet Environment: Install the complete rack assembly inside a clean, dry control enclosure providing an IP20 minimum rating. Maintain clear ventilation paths above and below the power module to prevent localized heat accumulation beyond the +60 deg C threshold.
  • Primary Power Wiring: Connect input power lines using conductors sized for the 600 W nominal rating. Route the incoming AC lines through dedicated wire ducts separated from low-voltage DC communication cables to prevent electro-magnetic induction.

TSX P47425 Schneider Electric Power Supply | New & Original Stock

Item no : 21973094079
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 18 - Jul 23

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches