20% OFF shipping at lifisolutions.eu on orders over $79 + up to 10% OFF products
lifisolutions.eu
home > Wilkins 1-975XL2S | Reduced Pressure Backflow Preventer with Strainer > Wilkins 1-975XL2S | Reduced Pressure Backflow Preventer with Strainer
download picture
Wilkins 1-975XL2S | Reduced Pressure Backflow Preventer with StrainerThe Wilkins 1 975XL2S is a reduced pressure principle backflow preventer with integrated bronze 'Y' type strainer, designed for high hazard protection on potable water lines against backsiphonage and backpressure contamination. Key Specifications: Size: 1 1 4 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable Certifications: ASSE 1013, CSA B64. 4 End Connections: FNPT Threaded Other Related Variants: 3 4
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The Wilkins 1-975XL2S is a reduced pressure principle backflow preventer with integrated bronze 'Y' type strainer, designed for high-hazard protection on potable water lines against backsiphonage and backpressure contamination.

 

Key Specifications:

  • Size: 1 1/4 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, CSA B64.4
  • End Connections: FNPT Threaded

 

Other Related Variants:

  • 3/4-975XL2S: 3/4 Inches version
  • 1-975XL2S: 1 Inches version
  • 1 1/2-975XL2S: 1 1/2 Inches version
  • 2-975XL2S: 2 Inches version

 

Materials:

  • Low Lead Cast Bronze Body (ASTM B 584)
  • Low Lead Cast Bronze Access Covers (ASTM B 584)
  • Noryl™ Polymers
  • Silicone Elastomers
  • Buna Nitrile Elastomers
  • Stainless Steel Springs (300 Series)
  • Stainless Steel Fasteners (300 Series)
  • Stainless Steel Ball Valve Handles

 

Typical Installation:

The Wilkins 1-975XL2S shall be installed on potable water lines in accordance with manufacturer's instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. Installation shall be made so that no part of the unit can be submerged. If installed indoors, the installation shall be supplied with an air gap adapter to prevent flooding.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA Compliant C511; NSF/ANSI/CAN 61 and 372; UL Classified; C-UL Classified; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California

 

Features & Benefits:

  • High-Hazard Backflow Protection: Protects potable water supply from both backsiphonage and backpressure contamination where health hazards exist.
  • Integrated Strainer: Bronze 'Y' type strainer provides added protection against debris, reducing maintenance requirements and extending component life.
  • Lead-Free Compliance: Meets NSF/ANSI/CAN 61 and 372 requirements with less than 0.25% weighted average lead content for safe drinking water applications.
  • Serviceable Design: First and second checks are accessible for maintenance without removing the relief valve or entire device from the line, minimizing downtime.

 

FAQ

 

Q: What is the minimum and maximum installation height for the Zurn 1-975XL2S?

A: The Zurn 1-975XL2S must be installed at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.

Q: Can the Wilkins 1-975XL2S be installed outdoors?

A: Yes, the assembly can be installed outdoors with a protective enclosure. For indoor installations, an air gap fitting is required above the floor drain.

Q: Are the check valves serviceable without removing the entire unit?

A: Yes, both the first and second check valves are accessible for maintenance without removing the relief valve or the entire device from the line, allowing for easier servicing.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 1-975XL2S | Reduced Pressure Backflow Preventer with Strainer

Item no : 21021501041
sold recently : Login >>
US$ 637.00
Pay in 4 interest-free payments of $159.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 28 - Aug 2

Enjoy 20% off shipping

US$ 637.00

1-11

US$ 573.30

12-35

US$ 445.90

36-59

US$ 382.20

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches