Shopping security
The Triconex 3805H functions as a high-density Analog Input Module specifically engineered for the Triconex Safety Instrumented System (SIS). This 100% Brand New original module utilizes a Triple Modular Redundancy (TMR) architecture to acquire critical 4–20 mA signals from field transmitters. By processing each of its 32 channels through three independent paths, the 3805H ensures that no single hardware failure compromises the safety loop. It serves as the primary interface for monitoring pressure, flow, and level variables in SIL 3-rated Emergency Shutdown (ESD) and Fire and Gas (F&G) applications.
| Feature | Technical Details |
| Model Number | 3805H |
| Input Channels | 32 Independent Analog Points |
| Signal Type | 4–20 mA DC Current Loop |
| Architecture | Triple Modular Redundancy (TMR) |
| Safety Integrity | SIL 3 Compliant (IEC 61508) |
| Operating Temp | -40 °C to +70 °C (-40 °F to 158 °F) |
| Shock Resistance | 30 g, 11 ms duration |
| Vibration Resistance | 5–500 Hz, 2 g |
| Isolation | Channel-to-System Optical Isolation |
| Accuracy | High-precision for safety-critical monitoring |
Triple Modular Redundant Fault Tolerance: Three separate internal processing legs vote on every incoming analog signal. The 2oo3 (two-out-of-three) voting logic identifies and masks internal faults instantly, maintaining uninterrupted system operation even during a component failure.
High-Density Safety Monitoring: The 3805H provides 32 points in a single-slot module. This high density allows engineers to design smaller control cabinets and reduce the total number of Triconex chassis required for large-scale refineries or power plants.
Extreme Environment Resilience: A ruggedized hardware design allows the module to operate in temperatures ranging from -40 °C to +70 °C. This enables reliable performance in non-climate-controlled equipment shelters and harsh offshore environments.
Advanced Loop Diagnostics: The module continuously monitors the integrity of the 4–20 mA field loops. It detects open circuits, short circuits, and out-of-range transmitter signals immediately, providing real-time alerts via front-panel LEDs and system status bits.
Zero-Downtime Maintenance: The 3805H supports hot-swapping during active operation. Maintenance personnel can replace a module without shutting down the process, ensuring continuous protection for high-availability industrial assets.
Does the 3805H support HART communication?
The 3805H focuses on high-integrity 4–20 mA signal acquisition for safety. While it captures the primary analog variable with extreme precision, users typically utilize specialized HART-capable Triconex modules (like the 3721) if secondary digital instrument diagnostics are required.
What type of cabling do you recommend for the 3805H?
Always use high-quality, individual-pair shielded twisted cable. Ground the shields at the Triconex rack end to prevent electromagnetic interference (EMI) from distorting the 4–20 mA safety-critical data.
Can I use this module for non-safety control tasks?
Yes. While designed for SIL 3 safety applications, many facilities use the 3805H for critical process control to leverage its TMR fault tolerance and eliminate nuisance trips caused by standard PLC hardware failures.
Ships within 48 hours · Estimated delivery Aug 9 - Aug 14
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order