20% OFF shipping at lifisolutions.eu on orders over $79 + up to 10% OFF products
lifisolutions.eu
home > Wilkins 12-975XL3 | Reduced Pressure Principle Backflow Preventer, 1/2" > Wilkins 12-975XL3 | Reduced Pressure Principle Backflow Preventer, 1/2"
download picture
Wilkins 12-975XL3 | Reduced Pressure Principle Backflow Preventer, 1/2"NOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 12 975XL3 is a reduced pressure principle assembly designed to protect potable water systems from backsiphonage and backpressure contamination. Key Specifications: Size: 1 2 Inches Maximum Working Pressure: 175 PSI Maximum Working Temperature: 180F Notable Certifications: ASSE 1013, cUPC, CSA B64. 4 End Connections: FNPT threaded ANSI
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 12-975XL3 is a reduced pressure principle assembly designed to protect potable water systems from backsiphonage and backpressure contamination.

 

Key Specifications:

  • Size: 1/2 Inches
  • Maximum Working Pressure: 175 PSI
  • Maximum Working Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT threaded ANSI B1.20.1

 

Other Related Variants:

  • 112-975XL3: 1 1/2 Inches model size
  • 114-975XL3: 1 1/4 Inches model size
  • 1-975XL3: 1 Inch model size
  • 2-975XL3: 2 Inches model size
  • 34-975XL3: 3/4 Inches model size

 

Materials:

  • Low Lead Cast Bronze ASTM B 584 (Main valve body and access covers)
  • Stainless Steel, 300 Series (Fasteners and springs)
  • Silicone, FDA Approved (Elastomers)
  • Buna Nitrile, FDA Approved (Elastomers)
  • Noryl™ (Polymers)

 

Typical Installation:

Ideal for use where Lead-Free valves are required on potable water lines requiring protection against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE 1013; cUPC; CSA B64.4; UL Classified (less shut-off valves); C-UL Classified; AWWA C511; Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California; NSF/ANSI/CAN 61 and 372

 

Features & Benefits:

  • Lead-Free Compliance: Meets NSF/ANSI/CAN 61 and 372 standards with less than 0.25% weighted average lead content for safe potable water applications.
  • Dual Protection: Protects against both backsiphonage and backpressure contamination where potential health hazards exist.
  • Easy Maintenance Access: First and second checks accessible for maintenance without removing relief valve or entire device from the line, with shared single access cover and top-accessible test cocks.
  • Durable Construction: Low lead cast bronze body with Noryl™ internal components, stainless steel springs, and FDA-approved silicone and Buna-N elastomers for long-lasting performance.

 

FAQ

 

Q: What is the minimum installation height for the Zurn 12-975XL3?

A: The assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance.

Q: What is the minimum working water pressure required for the Wilkins 12-975XL3?

A: The minimum working water pressure is 25 PSI, with a maximum working water pressure of 175 PSI.

Q: Can the Zurn 12-975XL3 be used in outdoor installations?

A: Yes, the assembly can be installed outdoors with proper protective enclosure. For indoor installations, an air gap adapter should be supplied.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 12-975XL3 | Reduced Pressure Principle Backflow Preventer, 1/2"

Item no : 16494042097
sold recently : Login >>
US$ 455.50
Pay in 4 interest-free payments of $113.88 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 19 - Jul 24

Enjoy 20% off shipping

US$ 455.50

1-11

US$ 409.95

12-35

US$ 318.85

36-59

US$ 273.30

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches